SKU: NCTS-QSTROM-3K776

NCTS QSTROM 3K776 3000VA 2700W Online Double Conversion Tower UPS, Pure Sine Wave, 0ms Transfer, 6x 12V 7Ah Batteries, LCD, ECO Mode, RS232, For PCs, Servers & Network Gear | Black

$ 265.00

Description

Expert Features

● Continuous Power Protection: Double-conversion technology conditions incoming power continuously, keeping sensitive equipment protected through mains interruptions.

● Clean Power for Sensitive Electronics: A smooth sine-wave output helps compatible computers, servers and networking equipment operate reliably.

● Reliable Operation on Unstable Mains: Wide input tolerance and automatic frequency sensing accommodate fluctuating utility supplies and compatible generators.

● Uninterrupted Changeover to Battery: Maintains power to connected loads when the mains supply fails, without a break during AC-to-battery transfer.

● Intelligent Battery Management: Smart charging manages battery replenishment and helps maintain dependable backup readiness.

● Energy-Saving ECO Mode: Offers an alternative operating mode to reduce power losses when supply conditions permit.

● Cold Start Capability: Allows the UPS to start from battery power when utility electricity is unavailable.

● Clear Status Monitoring: The front LCD, status LEDs and audible alerts make power conditions, load and estimated remaining backup time easy to monitor.

● Intelligent Cooling: Automatically adjusts fan speed according to operating conditions.

● Comprehensive Equipment Protection: Monitors overloads, short circuits, overheating and abnormal battery conditions to support safe operation.

● System Monitoring and Integration: Serial communication supports UPS management, with optional interfaces available for compatible installations.

Expert Specifications

SpecificationValue
Product Identification
BrandNCTS
SeriesQSTROM Online Tower
Model3K776
GTIN6295151551974
Product TypeUninterruptible Power Supply (UPS)
TopologyOnline Double Conversion with Full Digital Control
Form FactorTower
ColourBlack
Rated Apparent Power3000VA (3kVA)
Rated Active Power2700W (2.7kW)
AC Input
Nominal Input Voltage208 / 220 / 230 / 240VAC
Input Voltage Range110–300VAC
Input Voltage Range at 100% Load176–264VAC
Input Power Factor≥0.99 with PFC
Input Frequency Range40–70Hz
Frequency Auto-Sensing50 / 60Hz
Generator CompatibilitySupported
AC Output
Selectable Output Voltage208 / 220 / 230 / 240VAC
Output Voltage Regulation±1%
Output Power Factor0.9
Output Frequency — Line Mode46–54Hz or 56–64Hz
Output Frequency — Battery Mode50 / 60Hz ±0.1%
Crest Factor3:1
Harmonic Distortion (THDv) — Linear Load≤3%
Harmonic Distortion (THDv) — Nonlinear Load≤5%
Output WaveformPure Sine Wave
Transfer Time — AC to Battery0ms
Transfer Time — Inverter to Bypass4ms (Typical)
Output Capacity at 208VACDerated to 80% of Rated Capacity
Efficiency & Operating Modes
AC Mode Efficiency91%
Battery Mode Efficiency88%
ECO ModeSupported
Cold StartSupported
Fan Speed ControlIntelligent Regulation
Battery & Charging
Battery Quantity — Standard Unit6
Individual Battery Voltage12V
Individual Battery Capacity7Ah
Typical Recharge Time4 Hours to 90% of Full Capacity
Maximum Charging Current7A
Charger DesignSmart Battery Charging
Monitoring & Status Indicators
LED IndicatorsLine, Battery, ECO and Bypass Modes; Low Battery, Overload and UPS Fault
LCD — Input ReadingsInput Voltage and Frequency
LCD — Output ReadingsOutput Voltage and Frequency
LCD — Load MonitoringLoad Percentage
LCD — Battery MonitoringBattery Voltage and Estimated Remaining Backup Time
LCD — Thermal MonitoringInternal Temperature
Audible Alarms
Battery ModeOne Beep Every 4 Seconds
Low BatteryOne Beep Every Second
OverloadTwo Beeps Every Second
FaultContinuous Beeping
Protection & Management
Short-Circuit ProtectionSupported
Overload ProtectionSupported
Overheating ProtectionSupported
Battery Overcharge ProtectionSupported
Battery Overdischarge ProtectionSupported
Low Output Voltage ProtectionSupported
Fan Fault AlarmSupported
Communication InterfaceRS232
Optional Communication InterfacesUSB / EPO / SNMP Card
Configurable Load SegmentsOptional
Physical Characteristics
Dimensions (W × D × H)191 × 460 × 337mm
Net Weight10kg
Operating Environment
Operating Temperature0°C to 40°C
Storage Temperature−25°C to 55°C
Relative Humidity20–95% RH at 0–40°C, Non-Condensing
Operating AltitudeBelow 1500m; Derating Required Above 1500m
Noise Level<50dB at 1m
Standards
SafetyIEC/EN 62040-1; IEC/EN 62477-1
EMCIEC/EN 62040-2
Referenced EMC Test StandardsIEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2