SKU: KSTAR-UA300

KSTAR UA300 Line-Interactive UPS 3000VA / 1800W With AVR LCD Display, Fast Charging, Auto Restart, Simulated Sinewave Generator Compatible, Backup Power, Four Output Sockets , 12V / 9Ah x4 Batteries

$ 153.00

Description

Expert Features

  • 3000VA / 1800W High-Capacity Power Output: The UA300 is built to handle heavy-duty loads, delivering stable backup power for high-end PCs, workstations, servers, networking equipment, and critical electronics.
  • Line-Interactive UPS Architecture: Actively regulates unstable utility power while minimizing battery usage, ensuring efficient operation and extended battery life.
  • Automatic Voltage Regulation (AVR Boost & Buck): Corrects over-voltage and under-voltage conditions without switching to battery, protecting connected equipment from power fluctuations.
  • Simulated Sinewave Output: Supplies simulated sinewave power during battery mode, providing reliable compatibility with computers, office devices, and network hardware.
  • Ultra-Fast Transfer Time: Seamlessly switches to battery backup in as little as 2–6 ms (10 ms max), keeping systems running without interruption.
  • Cold Start Function: Allows the UPS to power on directly from battery without AC input, ensuring availability during complete power outages.
  • Four Output Sockets: Provides power to multiple devices simultaneously, making the UA300 suitable for full workstation or small server setups.
  • High-Capacity Battery Configuration: Equipped with four 12V / 9Ah batteries to deliver extended runtime and consistent backup performance.
  • Fast Charging Capability: Recharges batteries up to 90% capacity within 6–8 hours, reducing downtime between power events.
  • Auto Charging At Off Mode: Continues charging the internal batteries even when the UPS is switched off but connected to AC power.
  • Auto Restart On AC Recovery: Automatically restores output power once utility power returns, eliminating the need for manual restart.
  • Built-In Self-Diagnostic Function: Continuously monitors system health to ensure reliable operation and early fault detection.
  • Comprehensive Protection System: Integrated overload and overcharge protection safeguards both the UPS and connected devices.
  • LCD Status Display: Provides real-time visibility of AC mode, battery mode, load level, battery level, input voltage, output voltage, overload status, faults, and battery low warnings.
  • Audible Alarm Notifications: Distinct alarm patterns instantly communicate battery mode, low battery, overload, battery replacement, or fault conditions.
  • Modem / LAN Surge Protection: Shields communication and network lines from power surges and voltage spikes.
  • Generator Compatible (Optional): Designed to operate reliably with generator power sources for extended backup scenarios.

 

Expert Specs

SpecificationDetails
ModelUA300
Capacity3000VA / 1800W
UPS TypeLine-Interactive
Nominal Input Voltage220 / 230 / 240 Vac
Input Voltage Range162 – 290 Vac
Input Frequency Range50 / 60 Hz ±10%
Output Voltage (Battery Mode)Simulated Sinewave, ±10%
Output Frequency (Battery Mode)50 Hz or 60 Hz ±1 Hz
Transfer TimeTypical 2–6 ms, 10 ms Max
Output Sockets4
Battery Type12V / 9Ah
Battery Quantity4 Batteries
Typical Recharge Time6–8 Hours (90% Capacity)
ProtectionOverload, Overcharge
DisplayLCD
IndicatorsAC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, Battery Low
Alarm – Battery ModeBeep Every 10 Seconds
Alarm – Battery LowBeep Every Second
Alarm – OverloadBeep Every 0.5 Second
Alarm – Battery ReplacementBeep Every 2 Seconds
Alarm – FaultContinuous Sound
Management InterfaceNONE
Supported OSNONE
Operating Temperature0°C – 40°C
Humidity Range0 – 95% (Non-Condensing)
Noise Level< 40 dB @ 1 Meter
Dimensions (W×D×H)144 × 432.5 × 207 mm
Net Weight23 kg
Safety StandardsIEC/EN 62040-1, IEC/EN 60950-1